Send Message
products

FN7 Air Load Break Switch

Basic Information
Place of Origin: XIAN, China
Brand Name: XG
Certification: ISO CCC
Model Number: FN7
Minimum Order Quantity: 1 SET
Packaging Details: WOODEN CASE
Delivery Time: 7-15 DAYS
Payment Terms: L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability: 2000SET
Detail Information
Type: Indoor Medium: Vacuum
Standard: GB, IEC Standard Function: Switch On And Off Normal Load Current
Installation Location: Power Plants Warranty: 12 Months
OEM: Yes Package: Exporting Standard Package
Rated Voltage: 7.2kV, 12kV Rated Current: 400A 630A, 1250A, 1600A, 2000A, 2500A, 3150A
High Light:

7.2kV Air Load Break Switch

,

12kV Air Load Break Switch

,

2500A Air Load Break Switch


Product Description

1. FN7 Type 10kv 11kv 12kv indoor air load break switch fuse unit pole mounted lbs

FN7-12 series indoor AC HV load switch is a gas-production HV load switch and fuse combination unit with arc quenching principle.It is applied in three-phase AC 50Hz power system with rated voltage 12kV for breaking the load current and making the short-circuit current.The fuse combination unit can break the short-circuit current and has the function of single-phase fuse three-phase tripping and breaking.It is the ideal selection for protecting the line, equipment and transformer. Its performance meets the requirements of national standards GB 3804-2004 High-voltage alternating-current switches for rated voltage above 3.6kV and less than 40.5kV and GB 16926-2009

 

2. Product parameter

 

Serial No. Item Unit YFN7-12 HV Load Switch
1 Rated voltage kV 12
2 Rated frequency HZ 50
3 Rated current A 630
4 Rated short-circuit breaking current of fuse kA ---
5 Rated breaking transfer current A ---
6 Main loop resistance μΩ ≤80
7 Rated active load breaking current A 630
8 Rated short-time withstand current(thermal stability current)/duration kA/s 20/4
9 Rated short-time withstand current(thermal stability current)/duration of earthing switch kA/s 16/2
10 Rated peak withstand current(dynamic current) kA 50
11 1 min power-frequency withstand voltage(effective value)to earth,phase-to-phase/isolating fracture kV/kV 42/48
12 Full-wave lightning impluse withstand voltage(peak) to earth,phase-to-phase/isolating fracture kV/kV 75/85
13 Mechanical life Time 2000
14 Rated opening operation voltage V ---
15 Time of switch opening triggered by breaking of fuse ms ---

 

3. Product Characteristics

 

small size

light weight
simple & reasonable structure
small operating force
reliable performance & convenient maintenance

 

4. Service Conditions


(1).Altitude≤1000m;
(2).Ambient temperature-25ºC-+ 40ºC;
(3).The daily average of relative humidity shall not be larger than 95% and the monthly average shall not be larger than 90%:
(4).The ambient air shall not be subject to the obvious pollution such as corrosive or combustible gas and steam;
(5).The site without fire hazards and explosion hazards;
(6).The site that the seismic intensity does not exceed degree 8; the gradient shall not exceed 5°

 

5. Technical detail

 

FN7-12外观及安装图2.png

 

6. Factory

 

 

 

7. Delivery

 

FN7 Air Load Break Switch 1

 

8. FAQ

 

1. Send the technical data, better for all useful information; we will make a good recommendation.

If possible please attach one reference picture to avoid any misunderstanding or any links from our website for we get a better understanding.

2. The lead time depend on quantity of order. Some standard type is on stock. Otherwise, it will take 3-15 days.

3. Usually shipped by sea, small order or urgent order we can send you by air.

4. All our activities are accredited to ISO 14001:2015 and IEC standard.

5. Technology ensure the quality satisfy international request.

Contact Details
Emma

Phone Number : +8613319220197

WhatsApp : +8613319220197